Ömer Aydoğan
pid autotune

M303 E0 S200 C8

bias: 92 d: 92 min: 196.56 max: 203.75
Ku: 32.59 Tu: 54.92
Clasic PID
Kp: 19.56
Ki: 0.71
Kd: 134.26
PID Autotune finished ! Place the Kp, Ki and Kd constants in the configuration.h

The Kp, Ki, and Kd values can be entered with:

 M301 P19.56 I0.71 D134.26 

In the case of multiple extruders (E0, E1, E2) these PID values are shared between the extruders, although the extruders may be controlled separately. If the EEPROM is enabled, save with M500. If it is not enabled, save these settings in Configuration.h.

For the bed, use:

 Bed: M303 E

M303 E0 S200 C8

 

bias: 92 d: 92 min: 196.56 max: 203.75
Ku: 32.59 Tu: 54.92
Clasic PID
Kp: 19.56
Ki: 0.71
Kd: 134.26
PID Autotune finished ! Place the Kp, Ki and Kd constants in the configuration.h

The Kp, Ki, and Kd values can be entered with:

 M301 P19.56 I0.71 D134.26 

In the case of multiple extruders (E0, E1, E2) these PID values are shared between the extruders, although the extruders may be controlled separately. If the EEPROM is enabled, save with M500. If it is not enabled, save these settings in Configuration.h.

For the bed, use:

 Bed: M303 E-1 S60 C8 

and save bed settings with:

 M304 P1 I2 D3 
 
To save to EEPROM use: M500
-1 S60 C8 

and save bed settings with:

 M304 P1 I2 D3 
 
To save to EEPROM use: M500

Tarih: 23.01.2020